EasyMax VSelf-MonitoringBlood Glucose SystemUSER’S MANUAL
9 Description of Sound WHEN the meter will speak WHAT the meter will say Tune on. Turn-on music and greeting Tone. Setting Language / Setting Volume
10 Table of Contents Chapter 1: Understanding Your Meter …...
11 Symptoms of High or Low Blood Glucose...34 Comparing
12 Chapter 1: Understanding Your Meter The EasyMax V Blood Glucose Meter Display- Shows results, messages, and results stored
13 The EasyMax V Accessories Blood Glucose Test Strip Test Strip Bottle Expiration Date Strip Insert Direction Hand Hold Area Edge to Apply Sample
14 Installing Batteries 1. Open the battery door on the back of the meter by pushing the tab in the direction of the arrow
15 Setting The Time and Date—First Time Use Setting the current time and date in your meter is important if you intend to use the meter memory.
16 Setting The Language and Volume—First Time Use 1. Press to adjust the language.(En= English, Es = Spanish) 2. And press to confirm the
17 Using EasyMax V Blood Glucose Test Strip Use only with EasyMax V Blood Glucose Meter. Run a control solution test every time you open a new bo
18 Chapter 2: Control Solution Testing Why Run A Control Solution Test We recommend that you run the EasyMax V Normal control test because it lets you
1 EasyMax V Self-Monitoring Blood Glucose System User’s Manual Please read this User’s Manual thoroughly before using your blood glucose mete
19 About The Control Solution Use only with EasyMax V test strips. Write the date you opened the bottle on the bottle label. The control solution
20 Running A Control Solution Test You need the meter, a test strip, and control solution. 1. Put a test strip into the meter in the direc
21 6. Touch the drop at the tip of the test strip. 7. The meter starts to count down from 5 seconds and then shows the result. 8. Do not
22 Understanding Control Solution Test Results The label on your test strip bottle shows the acceptable ranges for the Control Solutions. The result
23 Troubleshooting Checks Action 9 Was the test strip exposed to open air for a long period of time? Repeat the
24 Chapter 3: Testing Your Blood Glucose Using The Lancing Device The best depth setting is the lowest number that draws enough blood for a test. Tr
25 Inserting A Lancet Into The Lancing Device You must first load the lancet into the lancing device to get it ready for use. 1. Unscrew
26 3. Recap the front cap.4. Select the desired penetration depth. Note: Select 1-2 for soft or thin skin. 3 for average. 4-5 for thick o
27 5. Pull on the sliding barrel of the lancing device until it clicks and then release. Now the lancing device is ready. Do n
28 Running A Blood Glucose Test With Blood From Your Fingertip 2. Put a test strip into the meter in the direction of the arrow. The meter t
2 Dear EasyMax V SMBG System Owner, Thank you for using the EasyMax V Self-Monitoring Blood Glucose (SMBG) System. We designed this system to be depe
29 5. Gently squeeze and/or massage your fingertip until a round drop of blood on your fingertip. 6. Touch the blood drop at the tip of the t
30 Alternate Site Testing (AST) Understanding Alternate Site Testing Consult your health care professional before you begin using the forearm fo
31 What to do: Fingertip test only: If sick If blood glucose is low After exercising Two hours or less after eating
32 1. Massage the puncture area of forearm for a few seconds. 2. Press and hold the device with clear adjustable tip against the forearm. 3. Press the
33 Discarding Used Lancets 2. Please discard used disposable lancets according to the recommendations of your healthcare professional. 1
34 Understanding Your Test Results The EasyMax V Blood Glucose test strips are plasma referenced and calibrated for easier comparison to lab results.
35 Symptoms Of High Or Low Blood Glucose Being aware of the symptoms of high or low blood glucose can help you understand your test results and deci
36 Comparing Your Meter Result To A Lab Result A common question is how the blood glucose results on your meter compare to the lab results. Your blood
37 Chapter 4: Meter Memory, Setup Memory, Storing Test Results Your meter stores a maximum of 480 test results with the time and date of the test. You
38 Viewing & Deleting Test Results The meter provides 7, 14, 30, 60 and 90 days averaging to help track your blood glucose trend soundlessly.
3 Standard Accessories Your new EasyMax V Blood Glucose meter and accessories work together to measure the amount of glucose in your blood. The system
39 Meter Setup Using The Set Mode By using the set mode, you can personalize your meter to suit your needs. Here are the features you can customiz
40 Chapter 5: Maintenance and Troubleshooting Installing Batteries The meter uses two alkaline 1.5V (AAA) batteries. Batteries will normally last for
41 Cleaning Your Meter Caring for your EasyMax V SMBG system does not require special cleaning. Please keep the meter free of dirt, dust, bloodstain
42 Maintenance And Testing Your meter needs little or no maintenance with normal use. It automatically tests its own systems every time you turn it
43 Screen Messages And Troubleshooting Never make treatment decisions based on an error message. If you have any concerns, please contact your local d
44 System fault Action: Replace the batteries first. If Err appears again, please call Customer Service toll-free 866-994-3345. Test result
45 The ”HF” and thermometer icon appears. Temperature is too high, outside the required range of 50°F - 104°F (10°C - 40°C). Action: Relocate the me
46 Chapter 6: Technical Information Specifications Brand name EasyMax V Blood Glucose Meter Range 20 - 600 mg/dL Test time 5 seconds Memory sets
47 Limitation The test strips are used for fresh capillary whole blood samples. 1. DO NOT use neonate blood sample. 2. Extreme humidity may affect
48 10. Critically ill patients should not be tested with home-use blood glucose meters. 11. Interfering Substances depend on the concentration. Elev
4 Why is it so important to test blood glucose regularly? Testing your blood glucose regularly can make a big difference in how you manage your diab
49 Device Information EasyMax V SMBG System, EasyMax V Blood Glucose Test Strips, EasyMax V Blood Glucose Meter, EasyMax V Normal Control Solution,
50 Lancet Meets the requirements of MDD 93/42/EEC Manufacturer: SAE HAN MEDICAL CORP. # 700-113 PUB GOT-DONG, IL SAN-GU, GOYANG-CITY, KYUNGGI-DO, KOR
5 Important Information About Your New Meter EasyMax V blood glucose meter is designed and approved for testing fresh capillary blood from finger
6 Remove batteries if the meter will not be used for one month or more. Warning for potential biohazard: Healthcare professionals using this sys
7 Health-Related Information If you are very dehydrated, urinating frequently, low blood pressure, shock or hyperosmolar hyperglycemic nonketotic
8 Explanation of Symbols Left button Right button Date Memory Time Insert a test strip Result amount Battery Unit Volume English Temperat